Customization: | Available |
---|---|
Warranty: | 10 Years |
Nature of Source Flow: | DC/AC Inverters |
Still deciding? Get samples of US$ 1040/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make at Made-in-china.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model |
WHT-3600W
|
WHT-5000W | WHT-6000W |
Input (DC) | |||
Recommend max.PV input power | 8700 Wp | 10000 Wp | 11000 Wp |
Max. PV input voltage | 600V | ||
Min.operating PV voltage | 40V | ||
Start-up input voltage | 50V | ||
Rated PV input voltage | 360V | ||
No.of independent MPPT inputs | 2 | ||
Default No. of PV strings per MPPT | 1 | ||
Max. PV input current | 16A | ||
Max. DC short-circuit current | 20A | ||
Input/Output (AC) | |||
Max. AC input power from grid | 8700 VA | 10000 VA | 11000 VA |
Rated AC output power | 3680 W | 5000 W | 6000 W |
Max. AC output power | 3680 VA | 5000 VA | 6000 VA |
Rated AC output current (at 230V) | 16 A | 21.8 A | 26.1 A |
Max. AC output current | 16.7 A | 22.8 A | 27.3 A |
Rated AC voltage | 220V/230V/240V | ||
AC voltage range | 154V~276V | ||
Rated grid frequency | 50Hz/60Hz | ||
Grid frequency range | 45~55Hz/55~65Hz | ||
Harmonic (THD) | <3% | ||
Power factor at rated power | >0.99 | ||
Adjustable power factor | adj.0.8.overexcited/leading to 0.8 underexcited/lagging | ||
Grid Type | Single phase | ||
Efficiency | |||
Max. efficiency | 0.975 | 0.977 | 0.977 |
European efficiency | 0.97 | 0.973 | 0.973 |
Protection&Function | |||
Gird monitoring | Yes | ||
DC reverse polarity protection | Yes | ||
AC short circuit protection | Yes | ||
Leakage current protection | Yes | ||
Surge Protection | DC type /AC type | ||
DC swith(PV ) | Yes | ||
DC fuse(battery) | Yes | ||
Battery input reverse polarity protection | Yes | ||
Battery Data | |||
Battery Type | Li-ion battery | ||
Battery voltage range | 42-59V | ||
Max. charge current | 100 A | ||
Max. discharge current | 100 A | ||
Max. charge power | 5000 W | ||
Max.discharge power | 5000 W | ||
General Data | |||
Dimensions (W*D*H) | 600*365*180mm | 600*365*180mm | 600*365*180mm |
Packing Dimensions (W*D*H) | 677*546*324mm | 677*546*324mm | 677*546*324mm |
Net Weight | <27 kgs | <27 kgs | <27 kgs |
Gross Weight | <30 kgs | <30 kgs | <30 kgs |
Mounting method | Wall-mounting bracket | ||
Topology | Transformerless | ||
Degree of protection | IP65 | ||
Operating ambient temperature range | -25ºC~60ºC | ||
Allowable relative humidity range | 0~100% | ||
Cooling method | Natural convection | ||
Max. operating altitude | 4000m | ||
Display | LED indicator | ||
Communication | RS485/CAN/WLAN | ||
DI/DO | DI×1/DO×1/DRM | ||
DC connection type | MC4 | ||
Battery connection type | Screws & Fasteners | ||
AC connection type | Screws & Fasteners | ||
Backup Data(on grid model) | |||
Rated output power for backup load | 6000 W | ||
Rated output current for backup load | 27A | ||
Backup Data(off-grid model) | |||
Rated voltage | 220V/230V/240V(±2%) | ||
Frequency range | 50Hz/60Hz(±0.5%) | ||
Total output THDV for liner load | ≤2% | ||
Switch time to emergency model | ≤10 ms | ||
Rated output power | 3680 W /3680 VA | 5000 W /5000 VA | 6000 W /6000 VA |
Peak output power | 8400 VA,10s | ||
Certificates | |||
General certificates | IEC/EN 62109-1/2; EN61000 | ||
Grid Standard | EN 50438; RD1663; RD1699; G83; G59; G99; PTPIREE+NCRFG |